123-1P-50
×
Coax Bulk
123-1P-50

1/2" Flexible bulk RF coaxial cable

Cellular DAS · Public-safety LTE · 4G/5G FR1 (sub-3 GHz)

7447 · Available Stock to 28 days
$4.10 Premier · per ea
📄 Spec Sheet (PDF)

Sign in to see your contracted tier pricing — or call (949) 888-5548 for volume pricing.

  • Manufacturer: 123eWireless
  • MPN: 123-1P-50

Details

1/2" Flexible is a 50-ohm RF coaxial cable engineered for low-PIM, durable cellular feeder runs. Rated to 6 GHz.
Construction: Copper-Clad Aluminum inner conductor, Air Dielectric (PE Spine) dielectric, Annularly Corrugated Copper outer conductor (shield), Natural Plenum (CMP/CATVP) jacket.
Operating range -40 to 85 °C. Sold by the foot from continuous reels; cut to length on order.

Why this part

1/2" Flexible 50-ohm RF coaxial cable, engineered for low-PIM, durable RF interconnect.
I.

1. Electrical Characteristics

Required to build assembly
Nominal Impedance (Ω) 50
Frequency Range DC – 6 GHz
— Cable Attenuation Chart (Standard Test Frequencies) —
Cable Attenuation @ 600 MHz (dB/100 ft) 1.71
Cable Attenuation @ 1.9 GHz (dB/100 ft) 3.29
Cable Attenuation @ 2.6 GHz (dB/100 ft) 3.97
Cable Attenuation @ 3.5 GHz (dB/100 ft) 4.75
Cable Attenuation @ 6 GHz (dB/100 ft) 6.64
Velocity of Propagation (Vp) (%) 91
Dielectric Constant (εr) 1.21 (derived from Vp)
Time Delay (ns/ft) 1.12 (derived)
Capacitance (pF/ft) 23.2
Inductance (µH/ft) 0.058
DC Resistance — Inner Conductor (Ω/1000 ft) 0.45
DC Resistance — Outer Conductor (Ω/1000 ft) 0.58
Peak Power Handling (kW) 21.4
Average Power Handling @ 2 GHz (W) 1410
PIM Rating (dBc) -165
II.

2. Construction & Dimensions

— Identification —
Cable Family / Trim Code 1P
Commercial Name 1/2" Flexible
Cable OD — Overall 0.627 in / 15.93 mm
Cable Weight 0.270 lb/ft / 402 g/m
— Inner Conductor —
Inner Conductor — Material Copper-Clad Aluminum
Inner Conductor — Diameter (in) 0.1900
Inner Conductor — Construction Solid
— Dielectric —
Dielectric — Material Air Dielectric (PE Spine)
Dielectric — Diameter (in) 0.4640
Dielectric — Construction Air-Spaced
— Outer Conductor / Shield —
Outer Conductor — Type Corrugated Copper
Outer Conductor — Material Annularly Corrugated Copper
Outer Conductor — Diameter (in) 0.5400
— Jacket —
Jacket — Material Natural Plenum (CMP/CATVP)
III.

3. Mechanical Performance

Bend Radius — Single / Installation 3.00 in / 76.2 mm
Bend Radius — Repeated / Dynamic 5.00 in / 127.0 mm
Bending Moment 4.07 Nm / 3.00 ft-lb
Cable Pull Tensile 1112 N / 250 lb
Flat Plate Crush 110 lb/in / 192.6 N/cm
Cold Bend Temperature (operating min) (°C) -40
IV.

4. Environment

Operating Temperature Range (°C) -40 to +85
Storage Temperature Range (°C) -40 to +85
Installation Temperature Range (°C) -20 to +60