Spec sheet — click Save as PDF or use Ctrl+P / Cmd+P. Toolbar hides when printing.
← Back to product
123eWireless
Product Specification · Built in America · Ships Today
Generated 2026-10-23
123-195-50
CABLE
123-195-50

Low-Loss 195 bulk RF coaxial cable

Public-safety LTE · 4G/5G FR1 (sub-3 GHz) · 5G mid-band

Manufacturer: 123eWireless  ·  MPN: 123-195-50  ·  Legacy PN: 123-RF195
QRScan to buy
Buy Now →
Details

Low-Loss 195 is a 50-ohm RF coaxial cable engineered for reliable, durable RF interconnect. Rated to 8 GHz.

Construction: Solid BC inner conductor, Foam PE dielectric, Aluminum Tape outer conductor (shield), PE jacket.

Operating range -40 to 85 °C. Sold by the foot from continuous reels; cut to length on order.

Why this part

Low-Loss 195 50-ohm RF coaxial cable, engineered for durable, reliable RF interconnect.

I.Electrical Characteristics
Nominal Impedance (Ω)50
Frequency RangeDC – 8 GHz
— Cable Attenuation Chart (Standard Test Frequencies) —
Cable Attenuation @ 600 MHz (dB/100 ft)9.02
Cable Attenuation @ 1.9 GHz (dB/100 ft)16.45
Cable Attenuation @ 2.6 GHz (dB/100 ft)19.42
Cable Attenuation @ 3.5 GHz (dB/100 ft)22.76
Cable Attenuation @ 6 GHz (dB/100 ft)30.46
Velocity of Propagation (Vp) (%)80
Dielectric Constant (εr)1.56
Time Delay (ns/ft)1.27 (derived)
Capacitance (pF/ft)25.4
Inductance (µH/ft)0.064
DC Resistance — Inner Conductor (Ω/1000 ft)7.60
DC Resistance — Outer Conductor (Ω/1000 ft)4.90
Shielding Effectiveness (dB)≥ 95
Proof Voltage (V)1000
Peak Power Handling (kW)2.5
Average Power Handling @ 2 GHz (W)70
PIM Rating (dBc)
II.Construction & Dimensions
— Identification —
Cable Family / Trim CodeLL195
Commercial NameLow-Loss 195
Cable OD — Overall0.195 in / 4.95 mm
Cable Weight0.021 lb/ft / 31 g/m
— Inner Conductor —
Inner Conductor — MaterialSolid BC
Inner Conductor — Diameter (in)0.0370
Inner Conductor — ConstructionSolid
— Dielectric —
Dielectric — MaterialFoam PE
Dielectric — Diameter (in)0.1100
Dielectric — ConstructionFoam
— Outer Conductor / Shield —
Outer Conductor — TypeBraid + Foil
Outer Conductor — MaterialAluminum Tape (foil) + Tinned Copper (braid)
Outer Conductor — Diameter (in)0.1160
Overall Braid — Diameter (over braid) (in)0.1390
— Jacket —
Jacket — MaterialPE
Jacket — ColorBlack (default)
III.Mechanical
Bend Radius — Single / Installation0.50 in / 12.7 mm
Bend Radius — Repeated / Dynamic2.00 in / 50.8 mm
Bending Moment0.27 Nm / 0.20 ft-lb
Cable Pull Tensile178 N / 40 lb
Flat Plate Crush15 lb/in / 26.3 N/cm
Cold Bend Temperature (operating min) (°C)-40
IV.Environmental
Operating Temperature Range (°C)-40 to +85
Storage Temperature Range (°C)-70 to +85
Installation Temperature Range (°C)-40 to +60
Flame RatingCMG / outdoor — PE (derived from jacket)